Groeneveld Auto Greaser Manual & Troubleshooting Guide
A practical reference for Groeneveld single and twin auto greaser systems — common settings, fault codes and what to do when something isn't right.
If your Groeneveld auto greaser has a fault you can't resolve, call us on 0488 986 862. We service and repair Groeneveld systems on-site anywhere in South Australia — often diagnosing faults over the phone first.
About Groeneveld Auto Greaser Systems
The Groeneveld auto greaser is an automatic lubrication system designed for trucks, buses, excavators and mobile plant. It delivers measured amounts of grease to all lubrication points on a timed cycle — eliminating manual greasing and ensuring consistent lubrication under all operating conditions.
The Groeneveld single auto greaser runs one pump and one grease circuit, suited to smaller vehicles and light plant. The Groeneveld twin auto greaser features two independent pump and circuit combinations — designed for larger equipment with more grease points that benefit from segregated circuits.
Key Settings on the Groeneveld Auto Greaser Controller
Set based on machinery application and manufacturer recommendation. Most trucks: 30–60 min. Heavy plant: 15–30 min.
Set to deliver the right volume per cycle. Adjusted based on number of grease points and line length.
Time the system waits after detecting a fault before triggering the alarm. Default varies by model.
Trigger a full pump cycle manually using the test button on the controller. Used for commissioning and fault-finding.
Resetting the Groeneveld Auto Greaser Alarm
On most Groeneveld auto greaser controllers, you can reset an active alarm after addressing the fault by pressing and holding the test/reset button for 3–5 seconds. The exact method varies by controller model — refer to the label on your controller or call us if you're unsure.
Important: If the alarm returns immediately after reset, the underlying fault hasn't been resolved. Don't repeatedly reset without investigating — the system is protecting your machinery.
Groeneveld Auto Greaser — Common Faults & What To Do
Use this as a first-step reference. If you can't resolve the fault yourself, call us on 0488 986 862 — we can often diagnose Groeneveld faults over the phone before coming out.
Low grease level, blocked injector, pressure fault or controller error.
Check canister level first. If full, check for blocked outlets or pressure fault. Reset alarm per controller instructions. If fault persists, call us.
Empty canister, pump failure, blocked line or controller not triggering.
Check canister. Test with manual purge button. If pump runs but no output, check for line blockage. If pump doesn't run, controller or motor issue.
System cycling but grease not reaching points — blocked injectors or cracked lines.
Inspect injectors individually. Check hose lines for damage. Pressure-test the system. Call us if injectors need replacement.
Injector blockage or pressure imbalance on one circuit.
Check each circuit separately using the manual test cycle. Identify which line has no output and inspect injectors on that circuit.
Varies by code — refer to your system's controller manual for specific codes.
Note the error code and call us. We can advise on most Groeneveld controller codes over the phone.
When To Call a Groeneveld Specialist
Some Groeneveld auto greaser faults can be resolved on-site with a basic check. Others — particularly pump failures, controller issues, or injector blockages across multiple points — need a specialist with the right parts on hand. Call us when:
- The fault alarm returns immediately after reset
- The pump runs but no grease reaches the points
- The controller shows a persistent error code
- You've replaced the canister but the system still doesn't cycle
- You need a Groeneveld auto greaser part that's hard to source locally
- You're commissioning a new Groeneveld installation and need it dialled in correctly
Need a Groeneveld Auto Greaser Specialist?
We carry Groeneveld auto greaser parts and service systems on-site anywhere in South Australia. Call us — we'll often diagnose your fault over the phone before coming out.
